Key takeaways
- Eaves first, under the underlayment; rakes last, over the underlayment.
- IRC 2021 minimums: 2-inch overlaps, nails every 12 inches, metal 1/4 inch below the deck.
- Reversed order is the top failure — it lets wind-driven rain behind the metal.
- Skipping drip edge saves a roofer an hour and costs a homeowner rotted fascia.
How to install drip edge the right way: install it along the eaves before the underlayment goes down, then along the rakes after the underlayment, overlapping every joint at least 2 inches and nailing every 12 inches on center. Get that order wrong and the metal does nothing — water finds the seam and works into the deck edge.
Drip edge is a bent strip of metal — usually aluminum or galvanized steel — that caps the perimeter of the roof. It is one of the cheapest materials on the whole job, and one of the most commonly skipped. I have torn off roofs where the fascia was rotted through, all because somebody saved an hour by leaving this strip off.
What drip edge actually does
Drip edge does three jobs: it kicks water into the gutter instead of down the fascia, stiffens the shingle edge so the first course does not curl, and closes the deck-to-fascia gap where wind-driven rain and insects get in. Without it, the deck edge sits exposed to every rainstorm, and water wicks back into the fascia board.
The code spec, in plain numbers
This is not opinion — it is code. Section R905.2.8.5 of the 2021 International Residential Code (IRC) requires drip edge at eaves and rakes of shingle roofs: overlaps of at least 2 inches, metal extending at least 1/4 inch below the sheathing and 2 inches back onto the deck, fastened at most 12 inches on center. And the order rule, straight from the code: underlayment goes over the drip edge at eaves, under it at rakes. Some jurisdictions go further: Florida’s 8th edition code requires a 3-inch overlap and 4-inch fastening in high-wind zones (110 mph or greater, or roof height over 33 feet). GAF’s application instructions add that starter strip shingles should sit 1/4 to 3/4 inch past the eave and rake edges.
How to install drip edge: the order that matters
Step 1 — Eaves first. Start at a corner and work along the eave, nailing the drip edge flat to the deck with the lower leg hanging past the fascia. Overlap each new piece over the previous one by at least 2 inches, in the direction water flows — uphill piece laps over the downhill piece, never the reverse. Cut with aviation snips; keep the face tight to the fascia with no bowing.
Step 2 — Underlayment next. Roll the underlayment over the eave drip edge, so water running down the felt lands on the metal and off the roof. If the underlayment goes under the eave metal instead, water runs behind the drip edge and straight into the fascia.
Step 3 — Rakes last. Install the rake drip edge over the underlayment, same overlaps, same 12-inch nailing. Where rake meets eave, the rake piece laps over the eave piece — water running down the rake steps down onto the eave metal, not under it.

Step 4 — Nails high on the flange. Drive nails through the top flange, high enough that the next course covers them. Nails driven low sit exposed and back out over time. Same discipline as the shingle nailing pattern: fastener placement is the warranty.
Corners and the mistakes that cause callbacks
At an outside corner, either miter the two pieces at 45 degrees or cut one piece to wrap around the corner and fold it tight — never butt two square-cut ends together and hope sealant saves it. Sealant is not a joint; it fails in a year of thermal movement. Overlaps shorter than 2 inches are the other classic callback: wind lifts the joint and the deck edge swells. Never nail through the face of the drip edge where it shows — face nails rust and streak. Before shingles go on, run your hand along the run: any bowing or proud nail, fix it now — once the starter course covers the flange, nobody fixes it without a tear-off.
Why cheap quotes skip it
Drip edge costs almost nothing in material and about an hour of crew time on an average house, but skipping it is invisible from the ground on bid day. A quote that omits it looks cheaper, and the homeowner cannot see the difference until the fascia rots years later. If a bid does not list drip edge as a line item, ask about it before you sign — and check the material: non-corroding metal drip edge, not painted steel that rusts through, with a heavier gauge in high-wind and coastal areas.
For the flashing that meets drip edge at walls, read our guide on how to install step flashing that never leaks — the two details work as a system. More field guides for working roofers live on the Pro hub.
FAQ
Do you need drip edge on a re-roof, or only on new construction?
On any shingle re-roof, yes. The IRC requirement applies whether the deck is new or existing, and a tear-off is the one time the full perimeter is accessible. If your roofer says the old drip edge can stay, check it piece by piece — bent or rusted sections get replaced, not reused.
Can you install drip edge on an existing roof without removing shingles?
Partially. On eaves you can lift the first shingle course and slide drip edge in under the underlayment, but on rakes the metal belongs over the underlayment, which means lifting shingles. A retrofit is better than nothing, but it never seals as cleanly as drip edge installed during a full replacement.
What material and gauge should drip edge be?
Aluminum or galvanized steel, non-corroding, is the standard for asphalt shingle roofs. Match the gauge to the exposure — heavier in high-wind and coastal areas — and always follow the shingle manufacturer’s printed instructions, which the IRC requires installers to follow. If the manufacturer and the code disagree, the stricter of the two wins.
Disclosure: RoofAdviceHub is reader-supported. When you buy through links on our site we may earn an affiliate commission at no extra cost to you. As an Amazon Associate we earn from qualifying purchases.